Chinese Journal of Experimental Traditional Medical Formulae
Determination of Hesperidin in Compound OPG Tablet by HPLC
DOI:
Author:
Affiliation:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
    Abstract:

    Obective:To develop a HPLC method for determining Hesperidin in the Compound OPG Tablet.Method:The sample was sonicated for 30 min.The contents were determined by HPLC,with a C18 column a molile phare of methanol-water (41∶59) and detection wavelength at 283nm.Result:Hesperidin has a good linearity in the range of 0.05658~1.13μg,Y=2637.54768X-7.43358,r=0.9999,The average recovery is 104.94% and RSD=2.37%(n=5).Conclusion:The method is sensitive,reliable and speedy.It can used for quality control of Compound OPG Tablet.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:July 01,2002
  • Revised:
  • Adopted:
  • Online:
  • Published:

Address:

Postcode:100700

Phone:010-84076882

E-mail:syfjx_2010@188.com

® 2024 All Rights Reserved

Supported by:Beijing E-Tiller Technology Development Co., Ltd.